Screen Shot 2020-02-12 at 8.47.28 PM.png

Glass Lined Reactor CE Type


Reactor DIN 28136

TECHNICAL DATA

Nominal capacity

  • CE   1.600 - 32.000 L


Design data

  • Pressure: - 1 to +6 bar

  • Temperature : -25 to +200°C


Design and calculation codes

  • VSR/AD-Merkblatter/ASME VIII div.1/CE stamp

  • PED 97/23/EC module cat. IV


Construction tolerance

  • To DIN 28006 T2


Construction

  • CE : one piece construction with the agitator entry    

  • Port on the top end 


Jacket design

  • As standard type B1 acc. to DIN 28151

  • On request other types acc. to DIN 28151


Design of half-pipe coil

  • The half-pipe coil is supplied as an alternative to the jacket.

  • Shape of the fluid flow section : half-pipe (DIN 28128)

  • Zones : one or more to be agreed

  • Single or double circuit : to be agreed


Nozzles

  • Flanges to DIN 2501 PN 10

  • All glass-lined nozzle are complete with loose backing split flanges acc. to DIN 28150 Other flange standards (ANSI) on request


Gaskets

  • PTFE envelope type with stainless steel insert for all glass-lined connections


Agitator system

  • 3-retreat-blade impeller agitator acc. to DIN 

  • 28157 and beaver tail baffle(s) acc. to DIN 28146.  

  • Other agitator designs are supplied on request


Drive unit

  • Asynchronous three-phase electric motor, EEx-d certified

  • Speed reducer with ground profile gears

  • Connection between motor and reduction gear : direct monted

  • Pedestal acc. to DIN 28162 T1 (with drive flange acc. to DIN 28137)

OPTIONS

  • Bottom outlet glass-lined valve, stem design, manually driven or pneumatically driven or pneumatically actuated.

  • Light fitting, EEx-d certified

  • Agitating nozzles in the jacket inlets to increase the circulation velocity of liquid media in the jacket.

  • Glass-Lined tip with platinum mini-tip melted into glass for a fast-response 

  • Temperature probe, which can be combined with the electrodes for the continuous glass control probe (RP probe)

  • Control probes = Temperature: 2xPT100 completely glass-lined or by tantalum tip - pH or redox 

  • Detection of glass-lining failure (RP probe)

  • Glass-lined or PTFE-lined dip-pipes. Other corrosion resistant materials are also available. 

  • Sampling probe - Simple or continuous type with circulation washing pump and eventually pH probe on the circuit.

  • Atex check device for monitoring mechanical units 

  • Fast closing device

  • Powder charging device

  • Eventually others on request