RICHTER MODEL MNK
SEALLESS CHEMICAL MAGNETIC DRIVE PUMP
Conveyance of corrosive, hazardous and pure media.
Reinforced plain bearing engagement.
Linings PFA/PTFE, PFA-L, PE, PFA-P
Operating range
60 Hz operation. 0.1-600 m3/h* 0.4-2650 US gpm up to 95 m (310 ft) LC. Temp. -60 °C to 180 °C* (-75 °F to 360 °F)*; up to 16 bar (235 psi). Solids up to 50% and gas contents up to 5 %, depending on pump design. Higher operating temperatures to more than 200 °C (400 °F) and pressures to 25 bar (360 psi) available on request.
50 Hz operation. 0.1-600 m3/h* 0.4-2650 US gpm up to 95 m (310 ft) LC. Temp. -60 °C to 180 °C* (-75 °F to 360 °F)*; up to 16 bar (235 psi). Solids up to 50% and gas contents up to 5 %, depending on pump design. Higher operating temperatures to more than 200 °C (400 °F) and pressures to 25 bar (360 psi) available on request.
Features
Maximum reliability through plain bearings with SAFEGLIDE® PLUS dry running optimisation (option)
Minimised storage costs: pump can be adapted for a wide variety of operating conditions
Independent of changing operating conditions through universally resistant PFA lining
Highly service-friendly: few components, very little setting work
Specifications
Design - Long life grease or oil bath lubrication
Nominal Pressure - PN16
Housing Material - EN-JS 1049 / ASTM A 395
Flanges to ISO 7005-2, type B or flanges drilled to ASME B16.5 class 150, raised face
Certifications - 2006/42/EC Machinery Directive, 2014/34/EU Equipment explosive atmosphere