Operating range
Vortex pumps are preferably used for media with higher solids contents. In addition, they have relatively good gas/liquid pumping capability. Media are conveyed gently for pump and medium solids contents of up to roughly 50% by volume, depending on grain sizes and properties
Particle sizes of about 10 to 20 mm (2/5 - 4/5”), depending on the pump size
Long-fibre constituents
Gas contents of up to 5% by volume
Operating temperature: -60 to +180°C (-75 to 360°F), depending on design and operating pressure
Operating pressure up to 16 bar (235psi),depending on housing design
Version for elevated vacuum (at standstill) optional
Features
Maximum reliability through plain bearings with SAFEGLIDE® PLUS dry running optimisation (option)
Minimised storage costs: pump can be adapted for a wide variety of operating conditions
Independent of changing operating conditions through universally resistant PFA lining
Highly service-friendly: few components, very little setting work
Specifications
Design - Long life grease or oil bath lubrication
Nominal Pressure - PN16
Housing Material - EN-JS 1049 / ASTM A 395
Flanges to ISO 7005-2, type B or flanges drilled to ASME B16.5 class 150, raised face
Certifications - 2006/42/EC Machinery Directive, 2014/34/EU Equipment explosive atmosphere